Key technical properties of this product. Refer to the Technical Data Sheet for complete installation and performance information.
| Classification | Class 3; TDS states AS/NZS 4858 compliance for AS 3740 requirements |
|---|---|
| Mixing Ratio | One component; do not dilute |
| Coverage | Approx. 9–9.5 m² per 15 L pail after two coats; varies with porosity |
| Recommended Coats | Minimum 2 coats |
| Dry Film Thickness | Minimum 1.0 mm total dry film (0.5 mm each coat) |
| Hydrostatic Resistance | Not designed for negative hydrostatic head; Bostik Moisture Seal preparation specified |
| Elongation at Break | >600% |
| Tensile Strength | >1.5 MPa (as printed in TDS) |
| Recoat Time | 1–2 hours per coat at 23°C and 50% RH |
| Full Cure | Final drying 24 hours after last coat at 23°C/50% RH; flood test after 72 hours at 22°C/50% RH |
| Suitable Substrates | Concrete; cement-rendered masonry; fibre cement sheet; water-resistant plasterboard; specified Type A structural plywood |