Stellmann Non-Slip Clear PRO is a transparent, water-based, two-component polyurethane anti-slip coating system for correctly prepared and primed internal and external surfaces. This 15 m² kit is available in P3,
  • Choose P3, P4 or P5 slip resistance
  • Transparent finish preserves the existing surface
  • Water-based two-component polyurethane
Slip Rating:

H2O AI Product Support

Technical and product guidance for the item you’re viewing.

  • Single-coat application over Stellmann Clear Primer.
  • Suitable for correctly prepared tile, stone, compatible coatings, timber, metal and glass.
  • Touch dry in approximately 60 minutes; light pedestrian traffic after approximately 12 hours.
  • 1. Clean and correctly prepare the substrate in accordance with the current Stellmann instructions; the surface must be clean and dry.
  • 2. Apply Stellmann Clear Primer. The TDS specifies the primer is diluted 1:1 with water and allowed approximately 30 minutes to cure under standard conditions.
  • 3. Mechanically mix Part A and Part B at 5:1 by weight. For the P5 variant, add the supplied non-slip aggregate strictly in accordance with the current manufacturer instructions.
  • 4. Apply one even coat using the specified roller at approximately 72 g/m². Do not apply a second coat or back-roll unless the current manufacturer instructions expressly permit it.
  • 5. Protect from water and traffic during cure. Typical touch-dry time is approximately 60 minutes and light pedestrian traffic is permitted after approximately 12 hours under standard conditions.
  • 6. Do not apply where rain is imminent, relative humidity exceeds 85%, the substrate has excessive moisture or defective waterproofing, or where the coating will be permanently immersed.
  • Product type: clear anti-slip polyurethane coating system
  • Chemistry: water-based, two-component polyurethane
  • Slip-rating variants: P3, P4 and P5
  • Kit coverage: up to 15 m²
  • Mixing ratio: Part A : Part B = 5:1 by weight
  • Application: one coat over Stellmann Clear Primer
  • Typical application rate: approximately 72 g/m²
  • Touch dry: approximately 60 minutes
  • Light pedestrian traffic: approximately 12 hours
  • Application temperature: 15–35°C
  • Maximum relative humidity: 85%
  • Water exposure: resists rain and condensation; not suitable for permanent immersion
  • Finish: transparent / clear

Which Slip Rating Do I Need?

Stellmann Non-Slip Clear PRO is available in different slip ratings to suit different pedestrian environments. Select the rating according to the project conditions and required slip resistance.

P3 SoftSelected option

Lower-maintenance internal areas

Shopping malls, food courts, offices, hotel lobbies, residential living areas and internal stairs not frequently exposed to water.

P3Selected option

Internal wet and amenity areas

Residential showers, bathrooms, kitchens, internal stairs, amenities, hotel bathrooms, hospital and aged-care bathrooms, and communal changing areas.

P4Selected option

Outdoor and exposed pedestrian areas

Outdoor entries, walkways, external ramps, driveways, footpaths, car parks, balconies, verandas, courtyards, pool surrounds and communal showers.

P5Selected option

Higher-risk sloped or commercial areas

External ramps and footpaths steeper than 1 in 14, undercover loading docks and commercial kitchens.

Online kit options: P3, P4 and P5. P3 Soft is included here as system-selection guidance but is not currently a purchasable Shopify variant. Contact H2O Technical if P3 Soft may suit the project.

Not sure which rating you need?

Slip-rating requirements depend on the location, surface conditions and project use. Send us the application area and substrate and H2O Technical can help identify the appropriate system.

Ask H2O Technical

Choose by Application

Use these categories as an initial guide. The required slip classification must still be determined for the specific location.

Internal Wet Areas

  • Bathrooms and showers
  • Amenities
  • Changing rooms

Generally associated with the relevant P3/P4 system depending on project requirements.

Balconies & Outdoor Areas

  • Balconies and verandas
  • Courtyards and walkways
  • Outdoor entries

The TDS identifies P4 for many of these applications.

Ramps & Higher-Risk Areas

  • External ramps
  • Sloping driveways and footpaths
  • Loading areas and commercial kitchens

P4 or P5 may be required depending on application and slope.

Commercial & Public Areas

  • Hotel lobbies
  • Shopping centres and food courts
  • Offices and public amenities

Selection depends on wet exposure and the required slip resistance.

Add an editable surface or application image in the Theme Editor.

Slip Resistance Without Hiding the Existing Finish

A transparent topical coating designed to improve slip resistance while allowing the existing surface appearance to remain visible. A test area is recommended because substrate, sheen, application method and lighting can affect the final appearance.

  • Transparent
  • Water-based
  • Dual-component polyurethane
  • UV-resistant and non-yellowing
  • Interior and exterior use
  • Topical surface sealer that repels water

Important: This product is not intended to rectify failed waterproofing, rising damp or negative hydrostatic moisture conditions.

Suitable Surfaces

The TDS identifies compatibility with a broad range of properly prepared substrates used internally and externally.

Tiles & mineral surfaces

Tiles, ceramics, natural and engineered stone, marble, sandstone, terracotta, bluestone, slate and other porous stone materials.

Sheet & coated surfaces

Fibre cement, acrylic coatings, polyurethane coatings and epoxy coatings.

Other identified substrates

Timber, metal and glass, subject to preparation, adhesion testing and system assessment.

Adhesion and suitability must be confirmed where the surface contains unknown coatings, sealers, nano treatments or water-repellent treatments. Do not apply over nano or other repellent treatments without appropriate assessment and testing.

System Components

The complete installation is a prepared, primed and accurately mixed coating system—not coating alone.

Surface preparation

Thoroughly clean the substrate; remove dirt, dust, contamination, loose material and flaking coatings. Allow it to become completely dry.

Stellmann Clear Primer

Apply the nominated primer before Non-Slip Clear. Dilute 1:1 with water, apply a thin film, avoid puddling and allow approximately 30 minutes at room temperature.

Part A

Mechanically mix Part A at low speed for 5 minutes before use.

Part B

Measure and combine with Part A at 5:1 by weight using a clean vessel and electrical precision scale; mix at low speed for at least 5 minutes.

Slip-rating system

Use the system and particle component applicable to the nominated classification. P5/R12 specifically references Stellmann P5 particles.

Kit contents vary by selected rating. P5/R12 specifically uses the applicable Stellmann P5 particle system. Confirm the supplied components for the selected Shopify variant before application.

Typical Application Process

Follow the current TDS, Safety Data Sheets and installation manual. Complete a test area where substrate condition, adhesion or appearance is uncertain.

  1. Clean

    Remove dirt, dust, contamination, loose material and flaking coatings. Wash clean and allow the surface to become thoroughly dry.

  2. Prime

    Dilute Stellmann Clear Primer 1:1 with water. Apply a thin film without puddling and allow approximately 30 minutes at room temperature.

  3. Mix

    Mix by weight: Part A : Part B = 5 : 1. Pre-mix Part A, weigh accurately and mechanically mix the combined components at low speed for at least 5 minutes.

  4. Apply

    Apply one even coat at a nominal 72 g/m². Do not second-coat, dry roll or roll back into completed sections. Use mixed coating within 45 minutes.

  5. Cure

    Protect the area while curing. Temperature, humidity, porosity and application conditions affect drying and trafficability.

Part A + Part B Mixing Calculator

Enter the Part A weight. The 5:1 ratio is calculated by weight—not volume.

Required Part B40 g
Total mixed weight240 g

Use a clean vessel and electrical precision scale. Part B = Part A × 0.2; total mixed weight = Part A × 1.2.

Cure Timeline

Tack free90–180 min
Light pedestrian traffic12 hours
Full chemical cure5 days

Benchmark conditions: 23°C and 50% RH. Temperature, humidity and substrate porosity can alter cure times. The TDS also describes the coating as touch dry in approximately 60 minutes.

Application Conditions

Air temperature15°C–35°C
Substrate temperature15°C–35°C
Relative humidityMaximum 85%
Concrete moistureBelow 10%
  • Do not apply when rain threatens or RH is above, or likely to exceed, 85% shortly after application.
  • Do not apply over faulty waterproofing, high substrate moisture, rising damp or negative hydrostatic pressure.
  • Record substrate temperature, moisture, RH and dew point before application.
  • Do not start in direct sun above 30°C; contact Stellmann Technical regarding HVLP spray application.

Avoid These Common Application Errors

Do not mix by volume

Measure Part A and Part B by weight using an electrical precision scale.

Do not double-coat

The non-slip system is a single-coat application.

Do not roll back

Overlapping or double application can leave a translucent or whitish appearance.

Do not apply to damp substrates

Confirm the surface is dry and within the stated moisture limits.

Assess repellent treatments

Nano sealers and other repellent treatments can prevent adhesion.

Do not coat failed waterproofing

This topical coating is not a remedy for underlying waterproofing failure.

Technical Performance

FinishTransparent; satin when roller applied and matt when spray applied.
SystemTwo-component polyurethane; Part A : Part B = 5:1 by weight; one coat.
Nominal spreading rateApproximately 72 g/m²; practical rates vary with roughness, porosity, method and conditions.
Weather and waterExcellent exterior exposure resistance; resists rain and condensation; not recommended for permanent immersion.
Traffic and heatSuitable for low, medium and high pedestrian traffic; dry heat resistance up to 120°C.
Clean-up and storageWater clean-up; shelf life 1 year unopened when correctly stored away from sunlight and frost.

Tested Slip Resistance

Stellmann Non-Slip Clear PRO has been tested in accordance with AS/NZS 4586:2013. The TDS lists Wet Pendulum Slider 96 classifications P3, P4 and P5, and Wet Pendulum Slider 55 classifications P3, P4 and P5. P5/R12 is available with the applicable Stellmann P5 particle system.

The required slip classification must be determined for the specific location. The selected system, application method and manufacturer requirements must be followed; purchasing a kit alone does not establish project compliance or guarantee the installed classification.

Before You Order

Confirm the following project details before choosing a kit and slip rating.

Existing surface type
Internal or external application
Approximate area in m²
Wet or dry exposure
Slope or ramp conditions
Required slip rating, if known
Existing coating or sealer
Moisture condition
Project location

If you are unsure which rating or kit is appropriate, send H2O Technical a photo of the surface and a short description of the application.

Get Technical Advice

Technical Documents

Part A and Part B SDS fields are ready, but document links will remain hidden until the approved files are added in Shopify product metafields or these section settings.

Need Technical Advice?

Not sure if this product, slip rating or substrate preparation is right for your project?

Our technical team can help review the application area, surface condition and system selection.

Independent product advice backed by real-world waterproofing and construction experience.

Contact Technical Support
(07) 3667 9878

Monday–Friday
7:00 am – 3:00 pm AEST

Warehouse Stocked
Fast Australia-wide Delivery
Expert Technical Advice
Secure Checkout

Frequently Purchased Together

Compatible preparation, primer and application accessories for the selected system.